Kelvex Labs

Kelvex Cooling Expert

Enter your pressures and temperatures, or start from a symptom: KCE returns the most likely cause and the checks to run.

Expert system for industrial refrigeration and HVAC/R. Deterministic and offline.

  • HVAC diagnostics
  • Fault interpretation
  • Guided procedures
  • Contextual support
  • 251technical rules
  • 61recommended actions
  • 6calculation tools
  • 0connection required

Android · coming soon on Google Play

Real KCE screen: interactive refrigeration circuit showing pressures, temperatures and current on the compressor, condenser, valve and evaporator diagram.
Interactive circuit: change a value and the diagnosis recalculates instantly.

What is KCE?

Kelvex Cooling Expert is a platform built for technicians in industrial refrigeration, air conditioning, cold rooms and HVAC/R maintenance.

Its aim is to cut diagnostic time, improve technical accuracy and bring the most-used tools together for real interventions in the field.

Features

Everything you need in the field, in a single professional app.

Refrigeration calculators

  • Superheat
  • Subcooling
  • COP
  • Cooling capacity

Pressure-temperature

  • Current refrigerants
  • Fast search
  • Instant conversion

Professional converter

  • Temperature
  • Pressure
  • Power
  • Flow rate

Rule-based diagnostics

  • Fault interpretation
  • Recommendations
  • Guided procedures

Technical library

  • Refrigerants
  • Compressors
  • Valves
  • Components

Procedures

  • Commissioning
  • Preventive maintenance
  • Fault resolution

Real KCE screenshots

Screens captured from version 2.4 on Android — no retouching, no mockups. App interface shown in Spanish.

Real KCE screen — Unit status: list prioritised by wear, historical reliability and recurring incidents, with a score for each unit.
Unit statusPrioritised by wear, historical reliability and recurring incidents.
Real KCE screen — Three routes: interactive diagram, readings or symptom-guided. You choose based on what you have to hand.
Three routesInteractive diagram, readings or symptom-guided. You choose based on what you have to hand.
Real KCE screen — Six tools: P-T, superheat, subcooling, converter, electrical control and cold room sizing.
Six toolsP-T, superheat, subcooling, converter, electrical control and cold room sizing.
Real KCE screen — Per-unit history: condition score, last diagnosis and next recommended service.
Per-unit historyCondition score, last diagnosis and next recommended service.
Real KCE screen — Explained diagnosis: most likely cause and, below it, each reading against its expected value.
Explained diagnosisMost likely cause and, below it, each reading against its expected value.

Built for real installations

KCE embeds technical knowledge aimed at commercial and industrial systems.

Supported refrigerants

R134a R404A R407A R407F R448A R449A R452A R454C R513A R744 (CO₂) R717 (NH₃)

Compatible environments

Food industry Cold rooms HVAC Supermarkets Refrigerated logistics Heat pumps Industrial processes

A diagnosis you can justify

KCE does not guess: it evaluates your readings against 251 technical rules written by refrigeration engineers and returns the most likely cause together with the reasoning. No generative AI, no cloud, and no different answers to the same data.

  • Deterministic: same readings, same result
  • Every conclusion shows the measured value and the expected one
  • 61 recommended actions tied to the rules
  • Derived variables: superheat, subcooling, compression ratio
  • Works fully without signal, in the plant room or the cold store
Real KCE screen: diagnostic result showing the most likely cause, its estimated probability and a “Why this diagnosis?” section comparing each reading with its expected value.

Ask like a technician

From a symptom or from your readings, KCE pinpoints the most likely cause and lists the checks to run.

Case 1

Symptom

Low suction pressure

KCE diagnosis

Possible refrigerant shortage.

Check

  • Sight glass
  • Superheat
  • Possible leaks
Case 2

Symptom

High subcooling

KCE diagnosis

Possible refrigerant overcharge.

Verify

  • System charge
  • Condensing pressure
  • Condenser condition
Case 3

Symptom

Frozen evaporator

KCE diagnosis

Possible causes:

  • Insufficient airflow
  • Faulty fans
  • Ineffective defrost
  • Badly set expansion valve

Who it is designed for

Made for professionals working with refrigeration and air conditioning systems in demanding environments.

Refrigeration technicians
HVAC installers
Maintenance companies
Plant managers
Cold rooms
Food industry

Advantages

From scattered tools to one unified platform with built-in intelligence.

Before
  • Several apps
  • Scattered PDF manuals
  • Slow lookups
  • Manual searching
After
  • A single platform
  • Offline expert system
  • Tools in one place
  • Faster diagnostics

Privacy by design

KCE puts the professional’s privacy first. Technical data stays under the user’s control and features are designed following sound security and data-protection practice.

Security

Technical data protection and secure sessions.

Privacy

Your data stays under your control.

Transparency

Clear practices and honest communication.

Frequently asked questions

Important: KCE is a technical support tool and does not replace official documentation or the safety procedures established by manufacturers and regulations.

Built for professionals

HVAC/R Industrial Refrigeration Maintenance Cold Rooms Food Industry CO₂ systems NH₃ systems

Sharpen your technical work

Professional tools, technical knowledge and expert diagnostics from a single offline app.

Be among the first professionals to try Kelvex Cooling Expert.

Notify me at launch